The needles on Thin Layer Chromatography (TLC) syringes are coated from the point for 3/4” with a PTFE-coating. The coating reduces the surface tension between the needle and the liquid making it ideal for reproducible sample spotting. The TLC syringe is available as a cemented needle (SNTLC) or as a replacement needle to be installed into a standard removable needle (RN) syringe. To find the appropriate no needle syringe select general syringes and filter by termination and gauge. Choose the “RN” and “No Needle Included” options to see all syringes that can receive TLC needles. To find the appropriate TLC needle select the TLC option under “Needles” in the main product menu. Hamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. Calibrated precision syringes are available only at the time of purchase. To order a calibrated syringe, add the prefix "CAL" to the beginning of the syringe's part number. For example, to order a calibrated 701N, 10 μL syringe (part # 8O3OO), request part # CAL8O3OO.
  • TEKNISK SPECIFIKATION
  • Tillverkare
    Hamilton
  • Leveranstid
    7
  • Lager-/beställningsvara
    Beställningsvara
  • Volym
    250 µl
  • Typ av produkt
    Syringe
  • Instrument
    No
  • Modell
    No
  • Användnings-område
    TLC Syringe
  • Gas/Vätska
    Gas
  • Termination
    Large RN
  • Nåltyp
    Removable Needle (RN)
  • Gauge
    No Needle Included
  • Spetstyp
    No
  • Autoclavable
    Yes
  • Gas-steriliserbar
    Yes
  • Max tryck
    No
  • Max temp (C)
    115
  • Min temp (C)
    10
  • Nålens dödvolym
    N/A
  • Nålens innerdiameter
    No
  • Nålens ytterdiameter
    No
  • Innerdiameter
    2.30 mm (0.091'')
  • Ytterdiameter
    7.75 mm (0.305'')
  • Vätskeväg
    SST, borosilicate glass, PTFE
  • Nålens längd
    No Needle Included
  • Material
    No
  • Kolvtyp
    No
  • Volym per varv
    No
  • Serie
    1700
  • Modell-beteckning
    1725
  • Variant
    Standard
  • Applikation
    TLC|HPLC
  • Originaldel
    No
  • Kalibrerad version
    CAL7657-01
  • Digital version
    No
  • Tjocklek
    No
  • Spruttyp
    TLC Syringe
  • UNSPSC-kod
    41122001
  • Tullstatnr
    90183190
  • Brand/märke
    Hamilton
Relaterade produkter
Art.nr. CAL7657-01 Beställningsvara
Nya produkter
Art.nr. 39-49-01949 Beställningsvara
Art.nr. 80950 Beställningsvara
Art.nr. 91016 Beställningsvara
Art.nr. DN30S05-1046WT Beställningsvara
Art.nr. DN06S05-05E8AU Beställningsvara
Art.nr. PH12S05-1504QT Beställningsvara
Art.nr. UPFP-7100150 Beställningsvara
Art.nr. TB30S05-0520WX Beställningsvara
Kontakta mig Kontakta mig Alf Schau + 46 31 709 81 90 E-post