ECOPLUS Glass Column, SR, 10 mm ID, 0-250 mm, 0-19 ml, 50 bar, 2 µm

  • ECOPLUS glass column, SR-version, type 2 long pistons, 10 mm ID, 0-250 mm bed length, 0-19 ml volume, 50 bar pressure limit, 2 µm frit porosity

  • Artikelnummer: TAC10/250LG2-SR-2

  • Antal/fp: 1

Lägg till i favoritlista

Jämför

Du måste godkännas som kund hos Genetec för att använda den här funktionen

Redo för leverans

YMC Glass Columns
Biochromatography is widely used for highperformance downstream processing techniques for a wide range of compounds, including proteins, peptides or nucleic acids. When using various chromatographic techniques such as ion exchange, affinity or gel permeation chromatography, high-performance separation media are increasingly used and, as a result, higher demands are made on the quality of the column hardware.

Laboratory Scale:
ECO and ECOPlus Glass Columns

ECOPlus columns meet the highest criteria for professional laboratory use. Particular attention has been paid to the column volume ranges and the pressure resistance, so that high flow rates, performance and efficiency can be achieved.
• First choice for high pressure application (preparative HPLC)
• Pressure limit: 15–80 bar
• Columns with 5 mm ID available
• Compatible with any LC system
• For all types of silica and soft gels
• Aqueous buffers and organic solvents
• Temperature range 4 - 40 °C (AB) or 16 – 40 °C (SR)
• Easy self packing

ECOPlus columns are multi-purpose columns for all types of liquid chromatography applications even with high operating pressures. The columns are available in two versions:
1. Aqueous buffer version (AB):
For applications with aqueous buffers
2. Solvent resistant version (SR):
For applications with organic solvents

Three different combinations of pistons are available for a wide range of bed lengths and volumes. The solvent resistant pistons are equipped with Teflon chevrons for sealing, the AB versions with O-rings.

ECOPlus columns are suitable for the entire spectrum of normal phase and reversed phase chromatography as well as biochromatography. All columns are produced in the YMC Europe facilities in Germany. The high pressure resistance is guaranteed by a special construction of the column including the locking system (Quick-Lock). The high-quality columns are made using high precision CNC machines and undergo several rigorous quality controls before they are delivered.

What is the difference between Vario and Multivario options?
Adjustable and non-adjustable (fixed) pistons are available for the ECO columns.
Two different options are available for combining these two pistons:
1. Vario: One adjustable and one fixed piston
2. Multivario: Two adjustable pistons
The selection of the option depends on the required ranges of bed lengths and column volumes.
  • TEKNISK SPECIFIKATION
  • Tillverkare
    YMC
  • Leveranstid
    7-21
  • Lager-/beställningsvara
    No
  • Brand/märke
    YMC ECO
  • Innerdiameter
    10 mm
  • Bäddlängd
    0-250 mm
  • Maxlängd
    250 mm
  • Volym
    0-19 ml
  • Fritporositet
    2 µm
  • Pistonger
    2 long pistons
  • Version
    SR (Solvent Resistent)
  • Värme/Kyla
    No
  • Temperaturområde (°C)
    No
  • Maxtryck
    50 bar
  • Material i kontakt
    PTFE pistons, glass frits, PTFE chevrons, KPG borosilicate glass body
  • Material
    Glass
  • Material O-ring
    PTFE triple chevron lamellar seals
  • Material Pistong
    PTFE
  • Anslutningar
    ¼” – 28 fittings (four for 1/16” or four for 1/8” capillaries). The column is supplied with two M6 adaptors to allow direct connection to any LC-system.
  • Justering bäddlängd
    Multi-variable plunger at each end, each providing approximately 60mm bed height adjustment with “Quick-Lock” bayonet system (long plunger option provides approximately 120mm bed adjustment for either or both ends)
Nya produkter
Art.nr. OC30S05-10E8RU Beställningsvara
Art.nr. 1117-01 Beställningsvara
Art.nr. ECO15/120M4V
Redo för leverans
Art.nr. PV12S05-1030WT Beställningsvara
Art.nr. TAC35/125LPE0-AB-2
Redo för leverans
Kontakta mig Kontakta mig Alf Schau + 46 31 709 81 90 E-post