ECO Glass Column, AB, 25 mm ID, 645-750 mm, 375-390 ml, 15 bar, 16-40 µm

  • ECO glass column with heating/cooling jacket, AB-version, type 2 long pistons (Multivario), 25 mm ID, 645-750 mm bed length, 375-390 ml volume, 15 bar pressure limit, 16-40 µm frit porosity

  • Artikelnummer: ECO25/750M3V-K

  • Antal/fp: 1

Lägg till i favoritlista

Jämför

Du måste godkännas som kund hos Genetec för att använda den här funktionen

Redo för leverans

YMC Glass Columns
Biochromatography is widely used for highperformance downstream processing techniques for a wide range of compounds, including proteins, peptides or nucleic acids. When using various chromatographic techniques such as ion exchange, affinity or gel permeation chromatography, high-performance separation media are increasingly used and, as a result, higher demands are made on the quality of the column hardware.

Laboratory Scale:
ECO and ECOPlus Glass Columns

ECO columns are glass columns for use with almost all types of soft gels and medium pressure liquid chromatography applications. A heating/cooling jacket option can be supplied on request.
• First choice for medium pressure liquid chromatography (MPLC)
• Pressure limit 5–30 bar
• Heating/cooling jacket available
• 70 and 80 mm ID columns with column stands available
• Compatible with any LC system
• For all types of silica and soft gels
• Aqueous buffers and solvents
• Temperature range 4–40°C
• Easy self-packing

ECO columns are glass columns suitable for all types of soft gel and medium pressure (pressure limit 5 – 30 bar) liquid chromatography applications. With a choice of one or two adjustable length pistons, they are available in two versions: AB (aqueous buffer) for use with aqueous buffers and cold room applications and SR (solvent resistant) for all forms of normal and reversed phase chromatography. ECO columns are produced using high-precision CNC manufacturing. They are competitively priced and equipped with a screw-lock system which makes it possible to open and seal the column simply and quickly. Each column passes a quality control pressure test. A water-jacketed option can be supplied on request.

What is the difference between Vario and Multivario options?
Adjustable and non-adjustable (fixed) pistons are available for the ECO columns.
Two different options are available for combining these two pistons:
1. Vario: One adjustable and one fixed piston
2. Multivario: Two adjustable pistons
The selection of the option depends on the required ranges of bed lengths and column volumes.
  • TEKNISK SPECIFIKATION
  • Tillverkare
    YMC
  • Leveranstid
    7-21
  • Lager-/beställningsvara
    No
  • Brand/märke
    YMC ECO
  • Innerdiameter
    25 mm
  • Bäddlängd
    645-750 mm
  • Maxlängd
    750 mm
  • Volym
    375-390 ml
  • Fritporositet
    16-40 µm
  • Pistonger
    2 long pistons (Multivario)
  • Version
    AB (Aqueous Buffer)
  • Värme/Kyla
    Yes
  • Temperaturområde (°C)
    No
  • Maxtryck
    15 bar
  • Material i kontakt
    POM pistons, glass frits, Viton O-ring, borosilicate glass body
  • Material
    Glass
  • Material O-ring
    Viton
  • Material Pistong
    POM
  • Anslutningar
    The columns are supplied with different adapters to allow direct connection to any LC-system (e.g. ÄKTA sytem)
  • Justering bäddlängd
    Multi-variable plunger at each end, each providing approximately 60mm bed height adjustment with “Quick-Lock” bayonet system (long plunger option provides approximately 120mm bed adjustment for either or both ends)
Nya produkter
Art.nr. UPFP-7050600 Beställningsvara
Art.nr. DN12S05-10J0RU Beställningsvara
Art.nr. NH12S05-2520WT Beställningsvara
Art.nr. TPF12S03-1002WT Beställningsvara
Art.nr. CAS08SQ7-15Q1PT Beställningsvara
Art.nr. HS12S03-1004QC Beställningsvara
Art.nr. ECO15/200M4V-K
Redo för leverans
Kontakta mig Kontakta mig Alf Schau + 46 31 709 81 90 E-post