Digital Syringe 50 µl Kel-F Hub PST

  • 50 µl Digital Syringe, Luer Tip (LT) NDL Sold Separately

  • PartNo: DS80901

  • Qty/pkg: 1

Add to Wishlist

Add to Compare

You must be approved by Genetec to use this function.

Order Item

Reading graduations is always a challenge. The Hamilton Digital Syringe eliminates parallax errors by providing a digital readout on its integrated LCD screen. An adjustable plunger-stop guarantees reproducible plunger placement. Easily achieve precision up to 0.5% while dispensing volumes from 500 µL down to 50 nL. Hamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. Calibrated precision syringes are available only at the time of purchase. To order a calibrated syringe, add the prefix "CAL" to the beginning of the syringe's part number. For example, to order a calibrated 701N, 10 μL syringe (part # 8O3OO), request part # CAL8O3OO.
  • SPECIFICATION
  • Manufacturer
    Hamilton
  • Delivery Time
    7
  • Stock Type
    Beställningsvara
  • Volume
    50 µl
  • Type of Product
    Digital Syringe
  • Instrument
    No
  • Instrument Model
    No
  • Usage Area
    No
  • Gas/Liquid
    Gas
  • Termination
    Luer Tip (LT)
  • Needle Type
    Kel-F Hub
  • Gauge
    No Needle Included
  • Point Style
    No
  • Autoclavable
    Yes to 115C
  • Gas Sterilizable
    Yes
  • Maximum Pressure
    No
  • Maximum Temperature (C)
    115
  • Minimum Temperature (C)
    10
  • Std. Needle Dead Volume
    N/A
  • Needle ID
    No
  • Needle OD
    No
  • Internal Diameter
    1.03 mm (0.041'')
  • Outer Diameter
    7.75 mm (0.305'')
  • Fluid Path
    Borosilicate glass, PTFE
  • Needle Length
    No Needle Included
  • Material
    No
  • Plunger Style
    No
  • Volume per rotation
    No
  • Syringe Series
    1700
  • Model
    1705
  • Variant
    Digital Syringe
  • Application
    No
  • Original version PNo
    80901
  • Calibrated Version PNo
    CAL80901
  • Digital Version PNo
    No
  • Thickness
    No
  • Syringe Type
    No
  • UNSPSC Code
    41122001
  • Tariff Code
    90183190
  • Brand
    Hamilton
Related Products
PartNo CAL80901 Order Item
PartNo 80901 Order Item
PartNo 6509006 Order Item
New Products
PartNo BU30S05-05Q1QT Order Item
PartNo CT99S05-05H0RU Order Item
PartNo 5041IP-04010-025-05 Order Item
PartNo 5030IP-05046-005-20 Order Item
PartNo OS12S03-02Q1GC Order Item
PartNo 15-04102-HU Order Item
Contact me Contact me Alf Schau + 46 31 709 81 90 E-mail