EXP Trap Column Replacement Stems, Peptide, x

  • EXP2 Replacement Stems, 1.5µL, 10µm, Peptide, 3/pk (Pressure Limit : 6000psi)

  • PartNo: 15-04014-TN

  • Qty/pkg: 3

Add to Wishlist

Add to Compare

You must be approved by Genetec to use this function.

Order Item

The entire EXP®2 Stem Trap and reusable holder are only slightly larger than a standard HPLC fitting. Its slim architecture allows it to easily fit into crowded instrument compartments or to connect directly to tightly-spaced injection ports. When tightened by hand, the EXP2 Stem Trap seals to 8,700+ psi. All configurations incorporate wrench-flats to enable flawless sealing to 20,000+ psi (1,400+ bar). The unique packed floating stem installs directly into any 10-32 port and automatically adjusts to provide a perfect ZDV connection. The EXP System enables chemists to quickly remove detergents or salts which can affect the ionization process in MS work. This trapping technique can concentrate the sample directly on-line, allowing for increased recovery of precious sample material compared to off-line techniques. On-line trapping readily lends itself to automation for high-throughput analysis in UHPLC/MS applications. Specialized features, patented technology, precision engineering and state-of-the-art manufacturing make the new EXP2 Stem Trap an unbeatable choice for ultra high-pressure trapping applications.

The new EXP2 design incorporates integral ferrule into the front-end of the holder. No separate ferrule to lose.

KEY FEATURES
- Kit includes EXP®2 Stem Holder with fittings and 3 EXP® Stem Traps
- Rated to 6,000+ psi (410+ bar)
- Hand-tight and wrench-tight configuration
- Intended for many repeat uses
- Auto-adjusting ZDV connection
- Bed volumes from 0.17 µL to 2.6 µL
- Low-volume/low-dispersion cartridges
- Custom packing available
- For nano flow applications
- New EXP2 design incorporates integral ferrule into the front-end of the holder. No separate ferrule to lose.

COMPATIBLE HOLDER & INSERTS
EXP®2 Stem Holder
EXP®2 Stem Filters
  • SPECIFICATION
  • Manufacturer
    Optimize Technologies
  • Delivery Time
    No
  • Stock Type
    Beställningsvara
  • Length
    No
  • ID
    No
  • Particle Size
    No
  • Pore Size
    No
  • Phase
    Peptide
  • Phase 2
    No
  • Phase Name
    Peptide
  • Base Material
    No
  • Column Type
    Trap Column Replacement Stems
  • Particle Type
    No
  • Carbon Load
    No
  • pH-Range Low
    No
  • pH-Range High
    No
  • Endcapping
    No
  • Separation Mode
    No
  • Max. Pressure
    410 bar (6 000 psi)
  • Max. Temp
    No
  • Surface Area
    No
  • USP
    No
  • UNSPSC Code
    No
  • Tariff Code
    90279000
  • Brand
    EXP
  • Product Type
    HPLC Column
New Products
PartNo 760405.20 Order Item
PartNo P-417 Order Item
PartNo TA12S05-0104GC Order Item
PartNo PV12S05-H304QT Order Item
PartNo OC20S03-10J0RU Order Item
PartNo TM12S05-R504QT Order Item
PartNo OC12S05-05J0AU Order Item
Contact me Contact me Alf Schau + 46 31 709 81 90 E-mail