ECOPLUS Glass Column, AB, 50 mm ID, 340-500 mm, 670-980 ml, 30 bar, 10 µm

  • ECOPLUS glass column, AB-version, type 1 short / 1 long piston, 50 mm ID, 340-500 mm bed length, 670-980 ml volume, 30 bar pressure limit, 10 µm frit porosity

  • PartNo: TAC50/500SLPE0-AB-2

  • Qty/pkg: 1

Add to Wishlist

Add to Compare

You must be approved by Genetec to use this function.

Ready for Delivery

YMC Glass Columns
Biochromatography is widely used for highperformance downstream processing techniques for a wide range of compounds, including proteins, peptides or nucleic acids. When using various chromatographic techniques such as ion exchange, affinity or gel permeation chromatography, high-performance separation media are increasingly used and, as a result, higher demands are made on the quality of the column hardware.

Laboratory Scale:
ECO and ECOPlus Glass Columns

ECOPlus columns meet the highest criteria for professional laboratory use. Particular attention has been paid to the column volume ranges and the pressure resistance, so that high flow rates, performance and efficiency can be achieved.
• First choice for high pressure application (preparative HPLC)
• Pressure limit: 15–80 bar
• Columns with 5 mm ID available
• Compatible with any LC system
• For all types of silica and soft gels
• Aqueous buffers and organic solvents
• Temperature range 4 - 40 °C (AB) or 16 – 40 °C (SR)
• Easy self packing

ECOPlus columns are multi-purpose columns for all types of liquid chromatography applications even with high operating pressures. The columns are available in two versions:
1. Aqueous buffer version (AB):
For applications with aqueous buffers
2. Solvent resistant version (SR):
For applications with organic solvents

Three different combinations of pistons are available for a wide range of bed lengths and volumes. The solvent resistant pistons are equipped with Teflon chevrons for sealing, the AB versions with O-rings.

ECOPlus columns are suitable for the entire spectrum of normal phase and reversed phase chromatography as well as biochromatography. All columns are produced in the YMC Europe facilities in Germany. The high pressure resistance is guaranteed by a special construction of the column including the locking system (Quick-Lock). The high-quality columns are made using high precision CNC machines and undergo several rigorous quality controls before they are delivered.

What is the difference between Vario and Multivario options?
Adjustable and non-adjustable (fixed) pistons are available for the ECO columns.
Two different options are available for combining these two pistons:
1. Vario: One adjustable and one fixed piston
2. Multivario: Two adjustable pistons
The selection of the option depends on the required ranges of bed lengths and column volumes.
  • SPECIFICATION
  • Manufacturer
    YMC
  • Delivery Time
    7-21
  • Stock Type
    No
  • Brand
    YMC ECO
  • Internal Diameter
    50 mm
  • Bed length
    340-500 mm
  • Lenght (Max)
    500 mm
  • Volume
    670-980 ml
  • Frit Porosity
    10 µm
  • Pistons
    1 short/1 long piston
  • Version
    AB (Aqueous Buffer)
  • Heating/Cooling Jacket
    No
  • Temperature range (°C)
    No
  • Pressure Limit
    30 bar
  • Wetted parts
    PE pistons, PE frits, EPDM O-ring, KPG borosilicate glass 3.3 body
  • Material
    Polyethylene
  • O-ring Material
    EPDM
  • Piston Material
    Polyethylene
  • Connections
    ¼” – 28 fittings (four for 1/16” or four for 1/8” capillaries). The column is supplied with two M6 adaptors to allow direct connection to any LC-system.
  • Height adjustment
    Multi-variable plunger at each end, each providing approximately 60mm bed height adjustment with “Quick-Lock” bayonet system (long plunger option provides approximately 120mm bed adjustment for either or both ends)
New Products
Contact me Contact me Alf Schau + 46 31 709 81 90 E-mail