ECO Glass Column, AB, 10 mm ID, 520-750 mm, 44-58 ml, 30 bar, 10-16 µm

  • ECO glass column, AB-version, type 2 long pistons (Multivario), 10 mm ID, 520-750 mm bed length, 45-58 ml volume, 30 bar pressure limit, 10-16 µm frit porosity

  • PartNo: ECO10/750M0V

  • Qty/pkg: 1

Add to Wishlist

Add to Compare

You must be approved by Genetec to use this function.

Ready for Delivery

YMC Glass Columns
Biochromatography is widely used for highperformance downstream processing techniques for a wide range of compounds, including proteins, peptides or nucleic acids. When using various chromatographic techniques such as ion exchange, affinity or gel permeation chromatography, high-performance separation media are increasingly used and, as a result, higher demands are made on the quality of the column hardware.

Laboratory Scale:
ECO and ECOPlus Glass Columns

ECO columns are glass columns for use with almost all types of soft gels and medium pressure liquid chromatography applications. A heating/cooling jacket option can be supplied on request.
• First choice for medium pressure liquid chromatography (MPLC)
• Pressure limit 5–30 bar
• Heating/cooling jacket available
• 70 and 80 mm ID columns with column stands available
• Compatible with any LC system
• For all types of silica and soft gels
• Aqueous buffers and solvents
• Temperature range 4–40°C
• Easy self-packing

ECO columns are glass columns suitable for all types of soft gel and medium pressure (pressure limit 5 – 30 bar) liquid chromatography applications. With a choice of one or two adjustable length pistons, they are available in two versions: AB (aqueous buffer) for use with aqueous buffers and cold room applications and SR (solvent resistant) for all forms of normal and reversed phase chromatography. ECO columns are produced using high-precision CNC manufacturing. They are competitively priced and equipped with a screw-lock system which makes it possible to open and seal the column simply and quickly. Each column passes a quality control pressure test. A water-jacketed option can be supplied on request.

What is the difference between Vario and Multivario options?
Adjustable and non-adjustable (fixed) pistons are available for the ECO columns.
Two different options are available for combining these two pistons:
1. Vario: One adjustable and one fixed piston
2. Multivario: Two adjustable pistons
The selection of the option depends on the required ranges of bed lengths and column volumes.
  • SPECIFICATION
  • Manufacturer
    YMC
  • Delivery Time
    7-21
  • Stock Type
    No
  • Brand
    YMC ECO
  • Internal Diameter
    10 mm
  • Bed length
    520-750 mm
  • Lenght (Max)
    750 mm
  • Volume
    44-58 ml
  • Frit Porosity
    10-16 µm
  • Pistons
    2 long pistons (Multivario)
  • Version
    AB (Aqueous Buffer)
  • Heating/Cooling Jacket
    No
  • Temperature range (°C)
    No
  • Pressure Limit
    30 bar
  • Wetted parts
    POM pistons, glass frits, Viton O-ring, borosilicate glass body
  • Material
    Glass
  • O-ring Material
    Viton
  • Piston Material
    POM
  • Connections
    The columns are supplied with different adapters to allow direct connection to any LC-system (e.g. ÄKTA sytem)
  • Height adjustment
    Multi-variable plunger at each end, each providing approximately 60mm bed height adjustment with “Quick-Lock” bayonet system (long plunger option provides approximately 120mm bed adjustment for either or both ends)
New Products
PartNo 22-32-01295 Order Item
PartNo TM12S03-15F0RU Order Item
PartNo DN12S05-L5E8RU Order Item
PartNo DN30S05-10Q1QC Order Item
PartNo OS12S05-2503QT Order Item
PartNo 760483.46 Order Item
PartNo 762420.160 Order Item
PartNo BU30S05-R504QC Order Item
Contact me Contact me Alf Schau + 46 31 709 81 90 E-mail